• HOME
  • Le produit
  • Pour usage médical

Pour usage médical

LUCEM developpe des produits nouveaux et differencies

personnalises pour nos clients.

Champ d'application

Portables / Mobiles

Médical

Points Forts

  • Maintien de performances stables et haute définition
  • Meilleur niveau de qualité standard de l'industrie garanti

Spécifications du produit en un coup d'œil

제품 스펙 한눈에 보기
Parameter LUC-8M LUC-10M LUC-11M LUC-11L LUC-12M LUC-13L LUC-14U LUC-17U LUC_19U
Focal Spot (Smal/Large,mm) 1.0/2.0 0.6/1.2 0.6/1.5 0.6/1.5 0.6/1.2 0.6/1.2 0.6/1.2 0.6/1.2 0.6/1.2
Target Material W/Re W/Re W/Re W/Re W/Re W/Re W/Re W/Re W/Re
Target Angle(℃) 16 12 14 14 12 14 12 12 12
kV Range 40-125 40-125 40~125 40-125 40~150 40-150 40-150 40~150 40~150
mA Range(Large/Small) 570/340 500/200 800/290 800/290 700/300 600/260 1,000/400 1,200/500 1,200/500
Anode Speed (50Hz, min,rpm) 2,700 2,700 2,700 2,700 2,700 2,700 2,700 2,700 2,700
Anode Speed (60Hz, min,rpm) 3,200 3,200 3,200 3,200 3,200 3,200 3,200 3,200 3,200
Anode Speed (180Hz, min ,rpm) NA NA NA NA NA NA 9,700 9,700 9,700
Anode Heat Content(kHU) 140 150 200 200 300 300 300 400 600
Stator Resistance(Main/Aux,Ω) 33.5/64.0 33.5/64.0 33.5/64.0 33.5/64.0 28.5/58.0 28.5/58.0 28.5/58.0 20.0/50.0 20.0/50.0
Stator Capacitor(㎌) 24 24 24 24 24 24 24 30 30
Rating(kW at 0.1)-50Hz(L/S) 43/21 40/14.5 47/16.5 47/16.5 50/20 41/17 41/14.5 60/24 60/24
Rating(kW at 0.1)-60Hz(L/S) 47/22.5 43/16 50/18 50/18 54/22 45/19 45/16 64/26 64/26
Rating(kW at 0.1)-180Hz(L/S) NA NA NA NA NA NA 75/27 100/40 100/40
max Filament Current(L/S,A) 5.1/5.1 5.1/5.1 5.3/5.3 5.3/5.3 5.4/5.2 5.4/5.2 5.5/5.2 5.4/5.4 5.4/5.4
Filament Voltage-Large 7.7-10.4 7.7-10.4 10.6-14.4 10.6-14.4 11.9~16.1 11.9~16.1 12.7-17.1 16.0~18.0 16.0~18.0
Small 5.8-7.8 5.8~7.8 5.1-6.9 5.1-6.9 6.8-9.2 6.8-9.2 6.3-8.5 6.0~8.5 6.0~8.5
Housing Temperature 16-75℃ 16-75℃ 16-75℃ 16-75℃ 16~75℃ 16-75℃ 16~75℃ 16~75℃ 16~75℃
Weight (kg) 16 16 16 11.8 16 11.8 18 20 20
X-Ray Coverage 354x354
(at SID 750)
354x354
(at SID 835)
354x354
(at SID 710)
470X470
(at SID 1,000)
354x354
(at SID 835)
470x470
(at SID 1,000)
354x354
(at SID 835)
430X430
(at SID1,000)
430X430
(at SID1,000)
  • LUC-8M

  • LUC-10M

  • LUC-11M

  • LUC-11L

  • LUC-12M

  • LUC-13L

  • LUC-14U

  • LUC-17U

  • LUC-19U

  • LUC-8M

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage125kV
      • Focal Spot Size (Small/Large)1.0/2.0㎜
      • Anode Heat Content100kJ(140kHU)
      • X-ray Tube Ass’y Heat Content900kJ(1,250kHU)
      • Min. Anode Rotation Speed(60Hz)Min. 3,200rpm

    Description du produit.

    • Intended use: X-ray Tube assembly with double-focus rotating anode X-ray Tube LUC-8M is intended to be used for diagnostic X-ray equipment.
    • 125kV, 140kHU rotating anode tube which is designed for general radiographic procedures.
      - Tungsten-rhenium alloy faced TZM target of 16˚ and 74㎜ diameter
      - Available in the 1.0㎜ / 2.0㎜ focal spot combinations
      - Stator of min. 3,200rpm rotation speed
    • 900kJ heat content of X-ray Tube ass’y
    • Accommodated with IEC60526 type high voltage cable receptacles.
  • LUC-10M

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage125kV
      • Focal Spot Size (Small/Large)0.6/1.2㎜
      • Anode Heat Content111kJ(150kHU)
      • X-ray Tube Ass’y Heat Content900kJ(1,250kHU)
      • Min. Anode Rotation Speed(180Hz)Min. 3,200rpm

    Description du produit.

    • Intended use: X-ray Tube assembly with double-focus rotating anode X-ray Tube LUC-10M is intended to be used for diagnostic X-ray equipment.
    • 125kV, 150kHU rotating anode tube which is designed for general radiographic procedures.
      - Tungsten-rhenium alloy faced TZM target of 12˚ and 74㎜ diameter
      - Available in the 0.6㎜ / 1.2㎜ focal spot combinations
      - Stator of min. 3,200rpm rotation speed
    • 900kJ heat content of X-ray Tube ass’y
    • Accommodated with IEC60526 type high voltage cable receptacles.
  • LUC-11M

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage125kV
      • Focal Spot Size (Small/Large)0.6/1.5㎜
      • Anode Heat Content142kJ(200kHU)
      • X-ray Tube Ass’y Heat Content900kJ(1,250kHU)
      • Min. Anode Rotation Speed(180Hz)Min. 3,200rpm

    Description du produit.

    • Intended use: X-ray Tube assembly with double-focus rotating anode X-ray Tube LUC-11M is intended to be used for diagnostic X-ray equipment.
    • 125kV, 200kHU rotating anode tube which is designed for general radiographic procedures.
      - Tungsten-rhenium alloy faced TZM target of 14˚ and 74㎜ diameter
      - Available in the 0.6㎜ / 1.5㎜ focal spot combinations
      - Stator of min. 3,200rpm rotation speed
    • 900kJ heat content of X-ray Tube ass’y
    • Accommodated with IEC60526 type high voltage cable receptacles.
  • LUC-11L

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage125kV
      • Focal Spot Size (Small/Large)0.6/1.5㎜
      • Anode Heat Content142kJ(200kHU)
      • X-ray Tube Ass’y Heat Content750kJ(1,056kHU)
      • Min. Anode Rotation Speed(60Hz)3,200rpm

    Description du produit.

    • Intended use: X-ray Tube assembly with double-focus rotating anode X-ray Tube LUC-11L is intended to be used for diagnostic X-ray equipment.
    • 125kV, 200kHU rotating anode tube which is designed for general radiographic procedures.
      - Tungsten-rhenium alloy faced molybdenum target of 14˚ and 74㎜ diameter
      - Available in the 0.6㎜ / 1.5㎜ focal spot combinations
      - Stator of min. 3,200rpm rotation speed
    • 750kJ heat content of X-ray Tube ass’y
    • Accommodated with IEC60526 type high voltage cable receptacles.
  • LUC-12M

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage150kV
      • Focal Spot Size (Small/Large)0.6/1.2㎜
      • Anode Heat Content210kJ(300kHU)
      • X-ray Tube Ass’y Heat Content900kJ(1,250kHU)
      • Min. Anode Rotation Speed(60Hz)Min. 3,200rpm

    Description du produit.

    • Intended use: X-ray Tube assembly with double-focus rotating anode X-ray Tube LUC-12M is intended to be used for diagnostic X-ray equipment.
    • 150kV, 300kHU rotating anode tube which is designed for general radiographic procedures.
      - Tungsten-rhenium alloy faced TZM target of 12˚ and 74㎜ diameter
      - Available in the 0.6㎜ / 1.2㎜ focal spot combinations
      - Stator of min. 3,200rpm rotation speed
    • 900kJ heat content of X-ray Tube ass’y
    • Accommodated with IEC60526 type high voltage cable receptacles.
  • LUC-13L

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage150kV
      • Focal Spot Size (Small/Large)0.6/1.2㎜
      • Anode Heat Content210kJ(300kHU)
      • X-ray Tube Ass’y Heat Content750kJ(1,056kHU)
      • Min. Anode Rotation Speed(60Hz)3,200rpm

    Description du produit.

    • Intended use: X-ray Tube assembly with double-focus rotating anode X-ray Tube LUC-13L is intended to be used for diagnostic X-ray equipment.
    • 150kV, 300kHU rotating anode tube which is designed for general radiographic procedures.
      - Tungsten-rhenium alloy faced TZM target of 14˚ and 74㎜ diameter
      - Available in the 0.6㎜ / 1.2㎜ focal spot combinations
      - Stator of min. 3,200rpm rotation speed
    • 750kJ heat content of X-ray Tube ass’y
    • Accommodated with CLAYMOUNT MINI-75 type high voltage cable receptacles.
  • LUC-14U

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage150kV
      • Focal Spot Size (Small/Large)0.6/1.2㎜
      • Anode Heat Content210kJ(300kHU)
      • X-ray Tube Ass’y Heat Content900kJ(1,250kHU)
      • Min. Anode Rotation Speed(180Hz)9,700rpm

    Description du produit.

    • Intended use: X-ray Tube assembly with double-focus rotating anode X-ray Tube LUC-14U is intended to be used for diagnostic X-ray equipment.
    • 150kV, 300kHU rotating anode tube which is designed for general radiographic procedures.
      - Tungsten-rhenium alloy faced TZM target of 12˚ and 74㎜ diameter
      - Available in the 0.6㎜ / 1.2㎜ focal spot combinations
      - Stator of min. 9,700rpm rotation speed (180Hz)
    • 900kJ heat content of X-ray Tube ass’y
    • Accommodated with IEC60526 type high voltage cable receptacles.
  • LUC-17U

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage150kV
      • Focal Spot Size (Small/Large)0.6/1.2㎜
      • Anode Heat Content285kJ(400kHU)
      • X-ray Tube Ass’y Heat Content1,111kJ(1,500kHU)
      • Min. Anode Rotation Speed(180Hz)Min, 9,700rpm

    Description du produit.

    • Intended use: X-ray tube assembly with double-focus rotating anode X-ray tube LUC-17U is intended to be used for diagnostic X-ray equipment.
    • 150kV, 400kHU rotating anode tube which is designed for general radiographic procedures.
      - Tungsten-rhenium alloy faced TZM target of 12˚ and 100mm diameter
      - Available in the 0.6mm / 1.2mm focal spot combinations
      - Stator of min. 9,700rpm rotation speed (180Hz)
    • 1,111kJ heat content of X-ray tube ass`y
    • Accommodated with IEC60526 type high voltage cable receptacles.
  • LUC-19U

    Télécharger
    Renseignements sur le produit

    Spécifications du produit.

      • Maximum X-ray Tube Voltage150kV
      • Focal Spot Size (Small/Large)0.6/1.2㎜
      • Anode Heat Content444kJ(600kHU)
      • X-ray Tube Ass’y Heat Content1,111kJ(1,500kHU)
      • Min. Anode Rotation Speed(180Hz)Min. 9,700rpm

    Description du produit.

    • Intended use: X-ray tube assembly with double-focus rotating anode X-ray tube LUC-19U is intended to be used for diagnostic X-ray equipment.
    • 150kV, 600kHU rotating anode tube which is designed for general radiographic procedures.
      - Specially processed tungsten-rhenium alloy faced TZM target of 12˚ and 100mm diameter
      - Available in the 0.6mm / 1.2mm focal spot combinations
      - Stator of min. 9,700rpm rotation speed (180Hz)
    • 1,111kJ heat content of X-ray tube ass’y
    • Accommodated with IEC60526 type high voltage cable receptacles.